Often when it can be starting up, the pen motor starts and runs for 5-10 mere seconds, then transforms off.Obtain the design number off the rating plate in the burner compartment and write-up it right here.
Concord 80 Gas Furnace Series Of ProcedureAlso, properly see the series of procedure of the heater and write-up the collection of stuff you discover taking place when the strength is turned on to the heater and the thermostat is certainly turned up. ![]() Works for about another 5 seconds and halts After about 10 seconds, the motor starts once again. You are suffering from what Identity call inconsistent procedure of the inducer motor. The heater wont heat up unless the inducer engine is running. ![]() So the 1st point to do is usually to make use of an AC voltmeter to check out and discover if the thermostat is usually shutting off the inducer electric motor. Connect one check guide to chassis ground and the some other to the W airport on the furnace and observe if the 24 VAC from the thermostat stays on when the inducer motor shuts away from. If the inducer motor shuts off whén the 24 VAC shuts away from, after that its the thermostat that wants to be checked out. I tried to test to see if the electric motor halts when it provides 24V or if the 24V drops. I am going to have got to wait until it occurs again, then I will check the voltage. But discretion requires examining that out to recognize the issue for certain, and simply where its taking place. Im fresh to furnaces and have arrive across a issue Im expecting someone. I switched the device off at thé thérmostat but it held on running. Concord 80 Gas Furnace Code Light RemainedThen I taken the breaker and the error code light remained constant (zero blinking). Turning the thermostat on again I witnessed the flame come on for about fifteen secs. We replaced the board last season and were provided a clear bill of wellness. Its dripping thru the pan into the cupboard system (inbetween) and works its way over to the alternative tube where it leaks out between the condensate pipe getting out of the cabinet. I couldnt discover the leak, in a try to sell black area using a brilliant light. I was heading to test reseal the skillet and all its joints but the góop the OEM uses is unavailable (not for sale) I was wondering what to use that will have got Low VOC and dry in a several hrs at many. Any tips Changing the skillet would become a main fiasco having to detach Vic piping and getting rid of 2 coils of about 300 lbs each.and just God knows what else Identity bump into.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |